If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
City of los angeles standard retaining wall detail.
Reinforcing steel shall be deformed steel conforming to a s t m.
Concrete block units to be staggered running bond.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
Alternative design procedures justified in a geotechnical report may also be approved.
213 847 0700.
Metal bin type retaining wall.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
The standard plans are divided into several series.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
City of los angeles electrical plan check correction list.
Each series contains several standard plans.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
San diego municipal code chapter 14 article 2.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Concrete block units shall conform to astm c90.
Multiple cover details for sanitary sewer manholes.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
Informational page for pre approved standard plans.
Lap all steel 16.
Acceptable engineering criteria for retaining wall design.
Page 1 of 2 retaining or slough wall 4 0 high or less.
City of los angeles electrical plan check correction list.
Concrete block units to have vertical continuity of the cells unobstructed.
Build safe well and fast with the city of los angeles department of building and safety.
Back to standard plans main index.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Disabled access standard details notes for commercial buildings.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Retaining or slough wall 4 foot high or less 178 kb view.